⚡ Connect like a pro — future-proof your network with VCELINK!
The VCELINK 30-Pack CAT7/CAT6A RJ45 connectors deliver ultra-fast 10Gbps data transfer with metal shielding to prevent EMI. Featuring a pass-through design for easy wiring verification, 3-prong gold-plated contacts for enhanced conductivity, and durable flame-retardant strain relief boots, this kit is perfect for custom Ethernet cable builds requiring professional-grade performance and reliability.
S**Y
If you are installing 10Gbit over 300 feet using wire, these are the connectors.
These are the perfect connector for when you have to use a CAT6A shielded POE cable. I have terminated thousands of connectors. These make easy termination of CAT6A shielded POSSIBLE. I never had a failed connection with these, many failed connections with non-pass through on shielded CAT6A. I find CAT6 unshielded very easy to terminate when using a non-pass through connector. I am an expert, and I was an editor for the 10 Mbit to 10Gbit IEEE 802.3 Standard for twisted pair. A friend's customer wanted to run 10G between two buildings using a UPS for POE backup power and I suggested twisted pair copper wire for a distance of 320 feet. First I made sure all utility power was separated by a foot at least in conduit. Second I ordered a high quality all copper 23AWG CAT6A overall shielded cable with a Direct-Burial jacket. I confirmed the insulation size would fit the RJ45 and the exterior jacket would fit the boot and connector. This connector only works with 23AWG and staggers the wedges of the connector because RJ45 was designed for 24AWG. The pass through design insures every wedge of the connector makes a reliable connection with multiple teeth. The cable manufacturers recommend you use part of the discarded shield to wrap about the jacket clamped by the shield drain crimped by the connector shield covered by heat shrink before placing of the boot. Then place the connector in the correct tool, crimp and remove excess wire. Slide the boot over the connector and test. I charge fives times as much to terminate a CAT6A SHIELDED compared to CAT6. Use CAT6A on long haul 10G. Use shielded when you are near other Ethernet at the distant end on long haul. If you must mix with other Ethernet in a bundle over a maximum haul distance at 10Gbit, you may have to use individual strand shielded cable because foreign-distant-end cross-talk is the biggest noise interferer problem at over 200 feet causing errors. I would strongly recommend this connector if using CAT6A shielded cable. Don't use CAT6A unless you have to as CAT6 is perfect for 1Gbit in allmost all situations except when at longest length or in a tight bundle mixed with lots of short haul and very long haul.
D**N
High quality shielded connectors
Easy to use, sturdy
M**D
Get 22AWG or Thicker
These RJ45 headers are great HOWEVER Id recommend 22AWG+I bought cat6a cable that was 23AWG and they did not stay put in the boot prior to slipping on the head.They still worked out fine for me in the end after a little trial and error.Make sure your crimp tool has a cutter, makes your job much easier.
B**.
Works on cat6a
They work great on thicker wire.
B**N
Bad Design and Poor Quality
The holes in the connector are WAY too big! It allows the wires to squirm around in the hole and likely NOT make a connection! Garbage design. Do better.
D**R
Poor QA, Cheap connectors
Pros - When all pins are present after crimping, they work well, are sturdy, and consistent in testing. the boot is nice and the plastic on it allows for easy use thats soft on the fingers compared to other boots.Cons - They were quite the pain to get the pinout of the cabling put in right. then, i terminated about 24 different ends and out of those, 5 of them were missing a pin. had to sacrifce a connector to get these fixed. 3 stars. almost 1 if i kept finding missing pins.
J**.
Buena calidad
Buen calidad. gracias
K**
Know your wire's diameter, if more than 1.2mm, get these
I have CAT6a cable with shield and apparently the wire insulation is thicker than usual CAT6a? Not sure. But most connectors for Cat6a were only 1.2mm which was too small in my case.These have a guide that you put your wires through and then with the guide in place push the wires nicely and get the work done in a jiffy. These are not cheap from any angle but the ease and the buld quality justifiea the premium.
Trustpilot